What is the best underlayment for a tile roof?

Which underlayments go under clay and concrete tile, what the Virginia Residential Code requires by slope and why the underlayment is the real water barrier.

The best underlayment for a tile roof is a heavy, code-listed sheet that suits your slope and climate. The Virginia Residential Code names ASTM D226 Type II felt, ASTM D2626 Type I and ASTM D6380 Class M roll roofing, and requires two layers on slopes from 2.5:12 up to 4:12. Self-adhering membranes are a common upgrade.

Homeowners choose a tile roof for the tile. The part that keeps the house dry is the sheet under it. Clay and concrete tiles shed most of the rain and shield the layer below from sunlight, but wind-driven water gets past the laps, and the underlayment is what stops it reaching the deck.

That is why the underlayment decision carries more weight on tile than on shingles, and why it deserves a careful choice in a place like Virginia Beach, where tropical systems push rain sideways. This guide explains the options, what the code asks for and what tends to go wrong.

What is roof underlayment, and why do tile roofs depend on it?

Underlayment is the water-shedding sheet fastened or stuck to the roof deck before the visible roofing goes on. On an asphalt shingle roof it is a backup, because the shingles seal to each other. Tile is different. Tiles overlap but do not seal, so they work as a rain screen. Industry references on tile roofing describe the underlayment as the primary water barrier and the tile as the layer that protects it from ultraviolet light and physical damage. The Journal of Light Construction's tile field guide makes the same point: the drainage plane is the underlayment, not the top layer. Water that passes the tile runs down the underlayment to the eave. If that sheet fails, the roof leaks, however sound the tiles look.

What does the Virginia code require under tile?

The 2021 Virginia Residential Code covers clay and concrete tile in section R905.3. Tile may be installed on slopes of 2.5:12 or steeper. Underlayment must comply with section R905.1.1. For tile, Table R905.1.1(1) lists ASTM D226 Type II, ASTM D2626 Type I or ASTM D6380 Class M mineral-surfaced roll roofing where wind design is not required, and ASTM D226 Type II where it is. Application depends on slope. From 2.5:12 up to 4:12, the code requires not fewer than two layers. At 4:12 and steeper, it requires not fewer than one layer applied shingle fashion. These are minimums. The tile manufacturer's installation instructions also apply, and your local building official decides which wind provisions cover your address.

What types of underlayment are used under tile?

There are three broad groups. Asphalt-saturated felt is the traditional one. ASTM D226 Type II is the heavy grade often called 30-pound felt. It is proven and inexpensive but can dry out and tear with age. Mineral-surfaced roll roofing, the ASTM D6380 Class M product in the code table, is a tougher asphalt sheet with a granule face. Then come the modern upgrades. Synthetic underlayments are woven or spun polymer sheets that resist tearing and tolerate exposure during installation. Self-adhering polymer-modified bitumen membranes stick directly to the deck and seal around fasteners. Each product has to carry the right standard or an evaluation report for use under tile, so check the data sheet, not just the product category.

What does best really mean for tile underlayment?

Best means matched to the life of the tile and the weather on your site. Clay and concrete tiles are long-lived. The underlayment under them usually is not expected to last as long, so the practical goal is to choose a sheet that will not need replacing decades before the tile does. That points toward heavier and more stable materials. It also means resisting heat, since the space under tile gets hot. It means sealing around the nails or screws that hold battens and tiles. And it means surviving being walked on during installation. A two-layer system, or a self-adhering membrane at the eaves, valleys and penetrations with a quality sheet across the field, is a common way to meet all four.

How should underlayment be chosen for coastal Virginia?

Start with wind-driven rain. Atlantic hurricane season runs June 1 to November 30. Hurricane Matthew left roughly 10 inches or more of rain on Virginia Beach area gauges in October 2016, and Hurricane Isabel brought a gust of 83 mph to Norfolk Naval Station in 2003. In that kind of weather, water is pushed uphill under the tile laps. Sealed or self-adhering underlayment at the vulnerable areas earns its cost here. Next, consider fasteners. FEMA's coastal guidance says salt spray is heaviest near the surf and declines across the first few thousand feet inland, and it recommends stainless steel or thick hot-dip galvanized fasteners for corrosion protection. Last, humidity. Norfolk averages 49.18 inches of precipitation a year, so the sheet will see water often.

What goes wrong when the wrong underlayment is used?

Failures follow a pattern. A light felt meant for shingles is used under tile, and it becomes brittle and cracks along the battens. Laps are too short or run the wrong way, so water tracks sideways under the sheet. Valleys and wall junctions get a single layer where they need reinforcement. Fasteners are overdriven and tear the sheet. Debris builds up under the tiles and holds water against the underlayment until it rots. The signs inside are familiar: stains on ceilings after wind-driven rain, damp sheathing in the attic, and leaks that appear far from any visibly broken tile. Because the tile hides the sheet, these problems are usually found late. A roof inspection that lifts a few tiles at the eave tells you more than a look from the ground.

How long does tile roof underlayment last?

There is no single reliable public figure, and we would be wary of anyone who quotes one with confidence. Service life depends on the product, the number of layers, roof slope, attic ventilation, sun exposure and how well the tile above keeps light off the sheet. What is consistent across industry references is the relationship: the tile usually outlasts the underlayment. That is why tile roofs are often renewed by a method called lift and relay. The tiles are taken up, the old underlayment and flashing are replaced, and the sound tiles go back down. The Virginia Residential Code allows this in section R908.5, which permits existing slate, clay or cement tile to be reinstalled. Damaged, cracked or broken tile may not be reused.

Can new roofing be laid over an old tile roof?

No. The Virginia Residential Code is direct on this. Section R908.3.1.1 says a roof recover is not permitted where the existing roof covering is slate, clay, cement or asbestos-cement tile. So when a tile roof reaches the end of its service, the choice is between lift and relay with new underlayment, or a full replacement. Section R908.5 also requires existing flashings, vents and similar parts to be replaced where they are rusted, damaged or deteriorated. Weight is the other point to check. Tile is heavy, and section R908.2 requires the structure to be capable of supporting the roof covering system. A house built for shingles needs an engineer's opinion before anyone puts tile on it.

What should you ask a roofer about tile underlayment?

Ask five things. Which underlayment product will be used, and which ASTM standard or evaluation report does it carry? How many layers, given the slope of each roof section? What goes in the valleys, at the eaves and around chimneys, skylights and vents? What metal are the fasteners and flashings, given the distance from salt water? And is the plan a lift and relay or a full replacement? Get the answers in the written estimate. Tile roofing and roof inspection are among Domi Roofing's listed services, and the company works across 7 Hampton Roads cities from its Virginia Beach office. Whoever you hire, the underlayment line on the estimate deserves as much attention as the tile.

Common questions

What underlayment does the Virginia code require under tile roofs?

The 2021 Virginia Residential Code lists ASTM D226 Type II, ASTM D2626 Type I or ASTM D6380 Class M mineral-surfaced roll roofing for clay and concrete tile where wind design is not required, and ASTM D226 Type II where it is. Slopes from 2.5:12 up to 4:12 need at least two layers.

Is synthetic underlayment good for tile roofs?

It can be, if the specific product is approved for use under tile and rated for the heat that builds up there. Check the manufacturer's data sheet and the tile maker's installation instructions. Not every synthetic sheet sold for shingles is suitable.

Do tile roofs leak if a tile cracks?

Not always at once. The underlayment is the main water barrier, so a single cracked tile often does not leak right away. It does expose the underlayment to sunlight and water, which shortens its life, so replace broken tiles promptly.

What is a lift and relay on a tile roof?

The existing tiles are removed and stacked, the old underlayment and flashing are replaced, and the sound tiles are laid again. The Virginia code permits reinstalling existing clay or cement tile under R908.5, but not damaged, cracked or broken pieces.

What is the minimum slope for a tile roof in Virginia?

Section R905.3.2 of the Virginia Residential Code allows clay and concrete tile on slopes of 2.5 units vertical in 12 units horizontal or steeper. Slopes below 4:12 need double underlayment.

Can shingles or metal be installed over an existing tile roof?

No. Section R908.3.1.1 of the Virginia Residential Code does not permit a roof recover where the existing covering is slate, clay, cement or asbestos-cement tile. The tile has to come off first.

Tell us what is going on.

  • 5.0120 Google reviews
  • LicensedVirginia Class A contractor license 2705189482
Call us(757) 737-9286

Get an Estimate

Your details, step 1 of 3
What do you need?
How soon?

Request received.

We will call you shortly to confirm. Need us sooner? Call (757) 737-9286.

Rather talk now? (757) 737-9286

Want a price range first? Get an instant roof quote